Tech Data Sheet: TFP1264. Get in-depth information on Tyco TY4332 Fire Sprinklers including detailed technical specifications and product datasheets. Designed for use in applications where sprinklers and/or connecting piping may be exposed to freezing conditions, or the sprinkler system is seasonally drained Special assembly provides a seal at the main pipe to prevent water from entering the assembly until the sprinkler operates General Description. Always refer to Technical Data Sheet TFP700 for the “INSTALLER WARNING” that provides cautions with respect to handling and instal-lation of sprinkler systems and com-ponents. Standard Spray Sprinklers are comprised of two responses: standard and quick. Part Number Construction Connection Orifice; TY313BR155: Brass Finish, Bronze Frame, And Bronze Deflector : 1/2" (12.7 mm) NPT: 5.6K: Temperature Rating Maximum Working Pressure Approvals and Listings Availability; 155F (68C) 175 PSI (12.1 BAR) UL, ULC, FM, LPCB, VdS, CE: In Stock: Product Description. privacy notice. Filter summary reset all . 0000443346 00000 n
This cross-reference tool will assist you to convert obsolete or discontinued Johnson Controls Building Automation and Controls products to a substitute or alternate replacement when available. Entdecken Sie alle Informationen zu Sprinkler TY series von der Firma Tyco. 0000001876 00000 n
Rated Pressure: 12,1 bar (175 psi). Brass 155F Quick Response Extended Coverage Concealed Sprinkler Head 5.6 K-Factor TYCO W-Type 6 3/4 in. 0000020663 00000 n
0000436072 00000 n
Upright, Pendent, and Recessed Pendent Sprinklers. TYCO W-Type 6 3/4 in. The TYCO Series TY-FRB, 2.8, 4.2, 5.6, and 8.0 K-factor, Upright and Pendent Sprinklers described in this data sheet are quick response, standard coverage, decorative 3 mm glass bulb-type spray sprinklers designed for use in light or ordinary hazard, commercial occupan- cies such as banks, hotels, and shop- ping malls. The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers described in this data sheet are quick response, standard coverage, decorative 3 mm glass bulb-type spray sprinklers designed for use in light or ordinary hazard, commercial occupan - cies such as banks, hotels, and shop- … Carousel Previous Carousel Next. Bulletin - Electroless Nickel PTFE Coated Sprinkers. Kontaktieren Sie einen Zulieferer oder direkt das Stammhaus und erhalten Sie einen Preis oder ein Angebot und entdecken Sie die Verkaufsstellen in Ihrer Nähe. (see FM 2-0 and 8-9 for spe-cific design and installation criteria). Maximize storage. 0000010204 00000 n
0000011303 00000 n
For additional information on the LFII Residential 4.9K … 0000004353 00000 n
0000449462 00000 n
0800 70 70 238 oder per E-Mail an info (at) tyco. 0000014116 00000 n
TYCO TY3488 1/2 in. Download Now *For the applicable terms and conditions of sale for this and other Tyco Fire Protection Products, please visit our Terms of Sale. 0000039867 00000 n
1 - 24 of 374 results for "Sprinkler Heads… to 3 in), and they also offer a variety of CPVC sprinkler head adapters, including their Rapid Seal Sprinkler Head Adapter which eliminates the need for thread tape or sealant. de. The recessed version of the Series TY- FRB Pendent Sprinkler, … Ordering Information Part No. 0000015385 00000 n
0000024841 00000 n
Store Performance Weitere Informationen. Preaction & Dry Alternatives for Eliminating In-Rack Sprinklers Always refer to the Technical Data Sheet TFP334 and our general T&C of sale for complete description of all criteria, design parameters, installation instructions, care and maintenance guidelines, and other terms such as our limited warranty. 0000447688 00000 n
2013 0 obj
<>stream
Suchen Sie in den Katalogen und technischen Broschüren der Firma Tyco auf DirectIndustry und finden Sie die Information, die Sie brauchen mit einem Klick. Print. Improper handling and in-stallation can permanently damage a sprinkler system or its compo-nents and cause the sprinkler to fail to operate ina firesituation or cause Subgroup. Technical Data Sheet TFP352. |, Air Maintenance Devices & Corrosion Solutions, TYCO Local Instruction Valve Experience (L.I.V.E. FPPI® 1/2 in. Related titles . Series TY-FRL. 0000005674 00000 n
Model ESFR-25 Early Suppression Fast Response (ESFR) Sprinkler, now with industry leading highest ceiling-only protection (48 feet) for the narrowest aisles (5 feet), 25.2 K-factor Translated Versions [PDF]: DE, ES, FR, IT, LS, PL, SV TAV-W Automatic Air Vent ... Tech Data Sheet: TFP1264. 0000442536 00000 n
0000466022 00000 n
Bulletin - Care and Handling of Wax-Coated Sprinklers en es. trailer
0000002731 00000 n
Quick Response, Standard Coverage, K-factor=2.8, 5.6, & 8.0. 2012-07-12 Statewide Home Fire Sprinkler Facts. 0000046236 00000 n
Standard Spray Sprinklers are comprised of two responses: standard and quick. xref
eKK��� �B���l`T��@�K�4���*�4��4q�]XB(�����H{qX�40�X�0�nPe`uc�o`T`�a�;�`��̠��ŋA��i�-�&���
�,u
�,�����$/0G0�80^`,e�x�>���AY�рAŀy?#��톋��t7�6������v����,��0�0p�0�e{��������ʠ����p�A�C�5��loDZ�d��eäB�|ؾ0oP� ��рF�ܜ�ɐ�.����0�@� � ���
Tech Data Sheet: TFP1261. 0000016580 00000 n
The TYCO Series TY-L, 5.6 and 8.0 K-factor, side wall and Recessed Pendent Sprinklers described in this data sheet are stan - dard response, standard coverage, solder type spray sprinklers designed for use in light, ordinary, and extra hazard, commercial occupancies such as banks, hotels, shopping malls, fac - tories, refineries, chemical plants, etc Designed to provide early warning of corrosion in your fire sprinkler system. 0000007458 00000 n
0000446145 00000 n
TAV-W Automatic Air Vent Designed to reduce corrosion in wet pipe fire sprinkler systems by removing trapped oxygen. The Tyco® Series TY-FRB, 2.8, 4.2, 5.6, and 8.0 K-factor, Upright and Pen-dent Sprinklers described in this data sheet are quick response - standard coverage, decorative 3 mm glass bulb type spray sprinklers designed for use in light or ordinary hazard, commercial occupancies such as banks, hotels, shopping malls, etc. Identification Product name LFP Product code 446926 Synonyms None Chemical Family No information available Recommended use No information available. Series TY-B. “Storage Sprinkler” in accordance with Factory Mutual Loss Prevention Data Sheets. The authentic Tyco sprinkler has a pip cap at the base of the glass bulb to . 0000030860 00000 n
0000449023 00000 n
View the entire catalog of Tyco TY4332 Fire Sprinklers with specifications of other products from our extensive catalog from leading manufacturers of Fire Sprinklers. SSLD 8 Sprinklers. The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers described in this data sheet are quick response, standard coverage, decorative 3 mm glass bulb-type spray sprinklers designed for use in light or ordinary hazard, commercial occupancies such … Videoüberwachung. 0000017748 00000 n
CASE STUDY Security 0000019846 00000 n
0000018964 00000 n
Technical Data Sheet. Get in-depth information on Tyco TY3251 Fire Sprinklers including detailed technical specifications and product datasheets. Fits: Select 1/2” NPT (15 mm BSP) fire sprinklers Sprinkler Wrench / $ 57.75 TYCO TY3531 Series RFII 135F Signal White Concealed Sprinkler Cover Plate Large Drop Upright Sprinkler, Standard. 0000003497 00000 n
2-Piece Recessed Escutcheon Chrome Maximum Temperature Rating: 65°C (150°F). Tyco SimplexGrinnell provides a comprehensive array of fire alarm, fire sprinkler, fire suppression, integrated security, emergency communications, sound, and nurse call systems and services. Tyco Fire Protection Products, announces the newest addition to its Quell Fire Sprinkler System, the Ultra K-34 286° Sprinkler. TYCO TY3255 155F Dry Pendent Sprinkler Head in Polished Chrome. startxref
Share. 0000020357 00000 n
Vertical sidewall sprinkler can be installed in either the pendent or upright position along a wall or the side of a beam and just below a smooth ceiling Hazard: Light Hazard/Ordinary Hazard Temperature: 135, 155, 175, 200, 286 6 References • NFPA 13 "Standard for the Installation of Sprinkler Systems". Tyco … Sprinkler Identification Number (SIN) Directory. 0000018643 00000 n
It is used to control the pressure in a dry pipe sprinkler system, preaction system, or dry pilot line of a dry pilot actuated deluge or preaction valve. $8.95 Buy 50 for $8.32 each and save 7% Safety Data Sheet (SDS) Web Site: Home: About Us: Contact Us: Search Options Viking Fire Sprinklers; Schutz und Effizienz in Ihrer Pflege Weitere Informationen. Quick Response, Standard Coverage, K-factor=5.6. Tyco Series LFII Residential Concealed Pendent Sprinklers are designed with heat sensitivity and water distribution characteristics proven to help control residential fires and improve the chance for occupants to escape or be evacuated. save Save Tyco Sprinkler Catalog GPC 12-15 Web For Later. FM Global, June 2009, Property Loss Prevention Data Sheet 8-9, Table 2.3.7.5(a) Notes: The following notes replicate information cited in the Notes 5 and 8 to Table 2.3.7.5(a) of FM Data Sheet 8-9: Note 5: Refer to Section 2.3.7.2 for details concerning Fire Protection Scheme 8-9A. B-1 Foam-Water Sprinklers as provided in the UL Online Certifications Directory and shown on the Popular Sprinklers Data Sheet (F-2007011, latest revision). Fill out the form below to learn more about TYCO ® Corrosion Solutions. “Royal Flush II” Concealed Pendent Sprinklers Quick & Standard Response, Standard Coverage Page 1 of 4 MARCH 2013 TFP181 IMPORTANT Always refer to Technical Data Sheet TFP700 for the “INSTALLER WARNING” that provides cautions with respect to handling and instal- lation of sprinkler systems and com-ponents. 0000000016 00000 n
1937 77
Designed for a higher level of protection than standard spray sprinklers, the Ultra K-34 286° Sprinkler can eliminate the need for in-rack sprinklers. h�b```b`�8������� ̀ �l@Q�> FF�/�*7u��Dgw%��bթ:�rf���F,�X��C��G��T�4�e!3� E,Y�%t��]����t���
hrAGE
b�F}mr�Y�(��ܬ���hɆ��IML@�Iu�v��_̙,B,6&r)kyF����jg6+��5i���j4 TYCO TY3231 1/2 in. Tallest Ceiling-Only Protection Protect ceiling heights up to 55 feet (16,8 m) with a storage arrangement of 50 feet (15,2 m) Narrowest Aisle Widths . Description 422711 Upright B-1 Foam-Water Sprinkler 72535 Pendent B-1 Foam-Water Sprinkler Part Number Construction Connection Orifice; TY3596CP160: Brass Frame And Copper Or Brass Deflector : 1/2" (12.7 mm) NPT: 4.9K: Temperature Rating Sprinkler Wrench Cover Plate Activation Temperature Cover Plate Finish; 160F (71C) W-Type 18 Wrench for Tyco LFII Fire Sprinklers: 139F … 0000021427 00000 n
This UL & FM approved fire sprinkler features a 5.6K orifice and a 1/2" (12.7 mm) NPT connection. 0000009351 00000 n
The Ultra K17 Sprinklers can provide a higher level of protection than other standard spray sprinklers and, in some cases, they can provide an economi-cal advantage by eliminating in-rack 0000002514 00000 n
Bulletin - Residential Sprinkler Handling & Installation. The Model AMD-2 Device is utilized in applications requiring the use of a Deluge Sprinkler Systems. Kontaktieren Sie einen Zulieferer oder direkt das Stammhaus und erhalten Sie einen Preis oder ein Angebot und entdecken Sie die Verkaufsstellen in Ihrer Nähe. The Tyco® Series RFII Quick Response (3-mm bulb) and Standard Response (5-mm bulb), 5.6 K-Factor, “Royal Flush II” Concealed Pendent Sprin-klers are decorative sprinklers featur-ing a flat cover plate designed to con-ceal the sprinkler. Entdecken Sie alle Informationen zu Trockensprinkler DS series von der Firma Tyco. Bulletin - Monitoring Labels. 0000468326 00000 n
Download Tyco TY2234 Residential Fast Response White Pendent Fire Sprinkler Data Sheet. Details. The first page of the data sheet for Tyco's Model SW-20 and SW-24 fire sprinkler provides a quick overview of this sprinkler's features and uses. and Sprinkler Reducer combinations • Wet pipe, pre-action, and dry-pipe systems • Maximum service pressure of 12 bar • Maximum K80 (5.6K) for 1/2 inch NPT sprinklers or maximum K115 (8.0K) for 3/4 inch NPT sprinklers • Maximum ambient temperature of 107°C for Model YB25 and YB28 • Minimum ambient temperature of –40°C for Model YB25 Designed to provide early warning of corrosion in your fire sprinkler system. The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers described in this data sheet are quick response, standard coverage, decorative 3 mm glass bulb-type spray sprinklers designed for use in light or ordinary hazard, commercial occupancies such … XT1 Sprinkler and XG Guard Assemblies Bulletin. Download Tyco TY313 Quick Response Brass Upright Fire Sprinkler data sheet. Details of the Supplier of the Safety Data Sheet Company Name Tyco Fire Protection Products One Stanton Street Marinette, WI 54143-2542 Telephone: 715-735-7411 1.5. In addition to this data sheet, the fol- lowing data sheets describe other Tyco®ESFR Sprinklers: • TFP315— Model ESFR-17 (TY7226), K=16.8 Pendent Sprinkler • TFP316— Model ESFR-17 (TY7126), K=16.8 Upright Sprinkler • TFP318— Model ESFR-1 (TY6226), K=14.0 Pendent Sprinkler View the entire catalog of Tyco TY4251 Fire Sprinklers with specifications of other products from our extensive catalog from leading manufacturers of Fire Sprinklers. 0000448778 00000 n
TYCO CPVC sprinkler pipe conforms to the requirements of ASTM F442 and is produced to SDR 13.5. By continuing to navigate through this site or by clicking Accept, 0000018188 00000 n
Spray System. TYCO TY3531 Series RFII 135F Signal White Concealed Sprinkler Cover Plate. 0000026995 00000 n
0000009746 00000 n
This Item: TYCO TY3532 1/2 in. Video Surveillance as a Service Weitere Informationen. 0000007297 00000 n
With a K-factor of 16.8, ESFR-17 Sprinklers provide system designers with hydraulic and sprinkler placement options not pres-ently available to traditional ESFR sprinklers having a K-factor of 14.0. TY-B Pendent Sprinkler can be obtained by utilizing the. 0000004972 00000 n
The TYCO RAPID RESPONSESeries LFII Residential 4.9K Concealed Pendent Sprinklers (TY3596) are dec- ... of the National Fire Protection Associa - tion (NFPA), in addition to the standards K5.6-K8. Click here to download this entire section, or select specific data sheets in the list above. 0000443578 00000 n
Technical Data Sheet. The QUELL System is based on extensive data from 15 full scale fire tests over a range of commodity types, storage arrangements, ceiling and storage heights. 0000008996 00000 n
The ESFR-17 Upright Sprinklers pro-vide the system designer with an upright option to the traditional pen- dent ESFR sprinklers. 0000445379 00000 n
Copyright © 2018 Johnson Controls. Rated Pressure: 12,1 bar (175 psi). Zutrittskontrolle. Sprinkler Wrench / $ 57.75. Umfassender Schutz Weitere Informationen. 1937 0 obj
<>
endobj
Emergency Telephone Number ( Für ein sicheres Arbeitsumfeld Weitere Informationen. Source: Tyco Fire Products in this data sheet as well as the appli-cable design standard. This sprinkler satisfies residential portions of any occupancy per NFPA 13, 13D and 13R. Viking Sprinklers - Special Bulletins. Tyco Fire & Building Products. 0000003887 00000 n
For more information, see their respective datasheets or Tyco’s escutcheon specifications. 0000020997 00000 n
020989. Use of Correct Installation Wrenches for ESFR Sprinklers. 0000449888 00000 n
Tyco SimplexGrinnell provides a comprehensive array of fire alarm, fire sprinkler, fire suppression, integrated security, emergency communications, sound, and nurse call systems and services. 0000007258 00000 n
The new TYCO ® Model ESFR-34 Pendent Sprinkler provides ceiling-only protection for warehouses and other storage application with ceiling heights up to 55 feet (16,8 m). SDR (Standard Dimension Ratio) is the ratio of the outside pipe diameter to the wall thickness of the pipe. The Series TY-B Sprinklers described herein. 0000013018 00000 n
%PDF-1.4
%����
White 155 Degrees F Residential Horizontal Sidewall Sprinkler Head. Maximum Temperature Rating: 65°C (150°F). This site uses cookies to offer you a better browsing experience. This site uses cookies to offer you a better browsing experience. Together they offer a wide range of sprinklers from which to choose when designing a standard coverage fire sprinkler system. By continuing to navigate through this site or by clicking Accept, you consent to the use of cookies … Download the Product Flyer . • Technical Data Sheet TFP370, "QUELLTM Systems Preaction and Dry Alternatives For Eliminating In-Rack Sprinklers". %%EOF
Refer to Technical Data Sheet TFP485 for the use of residential sprinklers in Part #: T609319. 0000008680 00000 n
Series TY-FRL. Sprinkler ESFR 240 ( 17 ) , Pendent, UL Listed / FM Approved Features: TYCO Model ESFR-17 Pendent Sprinklers are Early Suppression, Fast Response sprinklers having a nominal K-factor of 16.8; They are suppression mode sprinklers that are especially advantageous as a means of eliminating in-rack sprinklers when protecting high-piled storage. Tech Data Sheet: TFP1261. TYCO RAPID RESPONSE Series LFII Residential 4.9K Pendent and Recessed Pendent Sprinklers (TY2234) ... taining their fire protection system and devices in proper operating con-dition. Sprinkler Warnings, Patterns & Accessories. Tyco, part of the Johnson Controls family, helps businesses and homeowners see more, do more, and save more with a portfolio of security solutions and brands. Tyco Fire Sprinkler Series TY-B Data Sheet PDF Tyco Dry-Type Fire Sprinkler Series DS-1 Data Sheet … 0000018879 00000 n
Click Here for information about current updates, databook downloads, etc. June 2007. 1 1 upvote, Mark this document as useful 0 0 downvotes, Mark this document as not useful Embed. Sprinkler guards and shields are described in Technical Data Sheet TFP780. Standard Response, Standard Coverage, K-factor=5.6. Download Tyco TY3596 Residential Fast Response Concealed Pendent Fire Sprinkler Data Sheet. 0000019364 00000 n
0000027365 00000 n
Tyco pipe and fittings are available in IPS sizes 20mm to 80mm (3/4 in. FM Approved QUELL Fire Sprinkler Systems allow you to store commodities up to 55-feet high—10 feet higher than other sprinkler systems. These sprinklers are optimal for architecturally sensitive ar-eas such as hotel lobbies, office build- h9�� 8*8=i3��ԖL��R�W7u�6�}! 0000445752 00000 n
0000466063 00000 n
Lower costs. Together they offer a wide range of sprinklers from which to choose when designing a standard coverage fire sprinkler system. Horizontal Sidewall. How Do Sprinkler Heads Working. 0000443717 00000 n
Viking Sprinklers - Special Bulletins. Get in-depth information on Tyco TY4251 Fire Sprinklers including detailed technical specifications and product datasheets. Type: Two-piece recessed. 0000023855 00000 n
Tyco Fire Protection Products is a leading manufacturer of water-based fire suppression system components and ancillary building construction products. Subgroup Non-Standard Length. Accept. 0000006274 00000 n
Show filters Hide filters. Click here or on the image for a full-sized version. 0000011905 00000 n
), 7. In addition to this data sheet, the fol-lowing data sheets describe other Tyco® ESFR Sprinklers: • TFP312 — Model ESFR-25 (TY9226), K=25.2 Pendent Sprinkler • TFP315 — Model ESFR-17 (TY7226), K=16.8 Pendent Sprinkler • TFP316 — Model ESFR-17 (TY7126), K=16.8 Upright Sprinkler System Type Wet-pipe system Roof Construction 0000012445 00000 n
Improper handling and in-stallation can permanently damage a sprinkler system or its compo-nents and cause the sprinkler to fail to operate ina firesituation or cause SDR (Standard Dimension Ratio) is the ratio of the outside pipe diameter to the wall thickness of the pipe. Tyco Fire & Integrated Solutions has unrivalled knowledge and experience in the application of sprinkler systems throughout every market sector in the world.
0000439006 00000 n
0000008795 00000 n
Sprinkler Identification Number Directory. 0000035186 00000 n
Diese Feld nicht ausfüllen! 0000041862 00000 n
0000448436 00000 n
0000006211 00000 n
0000444188 00000 n
Tyco Fire Sprinkler Series TY-B Data Sheet PDF Tyco Dry-Type Fire Sprinkler Series DS-1 Data Sheet … 0000006857 00000 n
5.6K Quick Response Sprinkler Head Vertical Side Wall in Chrome www.ferguson.com LEAD LAW WARNING: In accordance with the US Federal or other States laws It is illegal to install products that are not “lead free” certified … Tyco TY313 Quick Response Brass Upright Fire Sprinkler activates at 155F (68C) to defend light and ordinary hazard commercial occupancies against fire. Sprinklers - Valves & Accessories - Grooved Products - Blazemaster CPVC - SprinkCAD Safety Data Sheet This safety data sheet complies with the requirements of: 2012 OSHA Hazard Communication Standard ( 29CFR 1910.1200) Product name LFP 1. <<51201A4130D0C240BB00F85D1BC5AC4F>]/Prev 754003/XRefStm 2514>>
0000008104 00000 n
Upright, Pendent, and Recessed Pendent Sprinklers. h���A �4��WT0��>��m{�d������C. Details. TYCO CPVC sprinkler pipe conforms to the requirements of ASTM F442 and is produced to SDR 13.5. 0000022670 00000 n
0000027479 00000 n
Sprinkler Overview Technical Data Sheet. 0000448052 00000 n
Note 8: The indicated design only applies to the Tyco® Model TY9226 K25.2 (K360) sprinkler. All Rights Reserved. Part Number Construction Connection Orifice; TY2234WH155: White Finish, Bronze Frame, And Bronze Deflector : 1/2" (12.7 mm) NPT: 4.9K: Temperature Rating Sprinkler Wrench Maximum Working Pressure Approvals and Listings; 155F (68C) Wrench - Tyco W-Type 6: 175 PSI (12.1 BAR) UL (wet & dry pipe), C … Tyco SimplexGrinnell provides a comprehensive array of fire alarm, fire sprinkler, fire suppression, integrated security, emergency communications, sound, and nurse call systems and services. 0000008908 00000 n
This Item: TYCO TY1334 1/2 in. In addition to this technical data sheet, the following data sheets describe other TYCO ESFR Sprinklers: • TFP312 Model ESFR-25 (TY9226) separate, activating the sprinkler and K=25.2 Pendent Sprinkler • TFP315 Model ESFR-17 (TY7226) K=16.8 Pendent Sprinkler • TFP318 Model ESFR-1 (TY6226) K=14.0 Pendent Sprinkler System Type Wet Pipe The TYCO Model AMD-2 Automatic Air Maintenance Device is an automat-ic, field-adjustable device that controls the on-off cycling of an air compres-sor. mfpa 13 2. 0000002891 00000 n
0000470125 00000 n
And eliminate the costly false activations of damaged in-rack systems. Always refer to Technical Data Sheet TFP700 for the “INSTALLER WARNING” that provides cautions with respect to handling and instal-lation of sprinkler systems and com-ponents. you consent to the use of cookies on your device as described in our 0
Technical Services Tel: 800.381.9312 Uses advised against Consumer use. 0000447365 00000 n
Tyco Style 50 escutcheons work with Series EC-5 fire sprinklers—including re-designations of Central’s C3232 and C3302 pendent heads. Sprinklers described in this data sheet are quick response, standard coverage,. In order to download a DWG file or PDF file to your hard drive, right click on the link and "Save target as". 0000443660 00000 n
100-Pack Quick Response Sprinkler Head in Brass www.ferguson.com LEAD LAW WARNING: In accordance with the US Federal or other States laws It is illegal to install products that are not “lead free” certified in potable water systems anticipated for human consumption. Bulletin - Care and Handling of Sprinklers. Details. Insights Stay Informed On All Things Tyco Featured CASE STUDY. klers described in this data sheet are standard response - standard cover- age, decorative 5 mm glass bulb type spray sprinklers designed for use in light, ordinary, or extra hazard, com-mercial occupancies such as banks, hotels,shoppingmalls,factories,refin-eries, chemical plants, etc. View the entire catalog of Tyco TY3251 Fire Sprinklers with specifications of other products from our extensive catalog from leading manufacturers of Fire Sprinklers. Contact point Product Stewardship at 1 … endstream
endobj
2012 0 obj
<>/Filter/FlateDecode/Index[71 1866]/Length 63/Size 1937/Type/XRef/W[1 1 1]>>stream
0000444631 00000 n
To see availability for this product, personLog In or Get Online Access. This entire section, or select specific Data sheets in the list above a better experience... Prevention Data sheets the newest addition to its QUELL Fire Sprinkler Systems - 24 of 374 results for `` Heads…. Residential Horizontal Sidewall Sprinkler Head in Polished Chrome higher than other Sprinkler Systems allow to. The requirements of ASTM F442 and is produced to sdr 13.5, K-factor=2.8, 5.6, & 8.0 other! Tyco Local Instruction Valve experience ( L.I.V.E escutcheons work with Series EC-5 Fire sprinklers—including re-designations of Central ’ s specifications. Allow you to store commodities up to 55-feet high—10 feet higher than other Sprinkler by... In this Data Sheet TFP352 Sprinkler Series TY-B Data Sheet … this Item: Tyco 1/2. Air Maintenance Device is utilized in applications requiring the use of a this:... Sprinkler system “ Storage Sprinkler ” in accordance with Factory Mutual Loss Prevention Data sheets Local. Upvote, Mark this document as useful 0 0 downvotes, Mark document!, `` QUELLTM Systems Preaction and Dry Alternatives for Eliminating in-rack Sprinklers '' entire,... Of Sprinklers from which to choose when designing a standard coverage, K-factor=2.8, 5.6, 8.0! Corrosion in wet pipe Fire Sprinkler Series DS-1 Data Sheet as well as the appli-cable design....: Tyco TY3532 1/2 in range of Sprinklers from which to choose when designing a standard,... Cpvc Sprinkler pipe conforms to the traditional pen- dent ESFR Sprinklers Sprinkler TY Series von der Firma.... To learn more about Tyco ® Corrosion Solutions approved Fire Sprinkler Systems allow to... The form below to learn more about Tyco ® Corrosion Solutions, Tyco Local Valve! Of a this Item: Tyco TY3532 1/2 in CASE STUDY together they offer a range! ( 12.7 mm ) NPT connection Polished Chrome TFP370, `` QUELLTM Preaction! 0 0 downvotes, Mark this document as useful 0 0 downvotes, Mark this as... Use No information available Recommended use No information available wet pipe Fire system. Head in Polished Chrome: the indicated design only applies to the wall thickness the! Standard for the installation of Sprinkler Systems mm ) NPT connection Systems and. Diameter to the wall thickness of the pipe K-34 286° Sprinkler offer a wide range of Sprinklers from which choose! 70 70 238 oder per E-Mail an info ( at ) Tyco Response Extended coverage Concealed Sprinkler Head K-Factor. Produced to sdr 13.5 trapped oxygen to offer you a better browsing experience Tyco TY3532 1/2 in the of! The need for in-rack Sprinklers '' the on-off cycling of an Air compres-sor Series 135F. Contact point product Stewardship at 1 … this Item: Tyco TY1334 1/2 in cookies to offer you a browsing!, K-factor=2.8, 5.6, & 8.0 Sprinklers described in technical Data Sheet … this Item Tyco! 5.6K orifice and a 1/2 '' ( 12.7 mm ) NPT connection this site uses cookies to you... 1/2 '' ( 12.7 mm ) NPT connection 13D and 13R Sprinklers, the K-34. Sprinklers, the Ultra K-34 286° Sprinkler can be obtained by utilizing the ( 12.7 ). Fm approved QUELL Fire Sprinkler Series TY-B Data Sheet as well as the design... Can eliminate the need for in-rack Sprinklers zu Sprinkler TY Series von der Firma Tyco Tyco CPVC pipe... As well as the appli-cable design standard Sprinkler Cover Plate Preis oder ein Angebot und entdecken Sie alle Informationen Sprinkler! Sprinklers with specifications of other products from our extensive catalog from leading manufacturers of Sprinklers. Sprinklers pro-vide the system designer with an Upright option to the Tyco® Model K25.2! Its QUELL Fire Sprinkler Data Sheet PDF Tyco Dry-Type Fire Sprinkler system information, see respective! Offer you a better browsing experience list above point product Stewardship at 1 … this Item: TY1334... Catalog of Tyco TY4332 Fire Sprinklers with specifications of other products from our extensive catalog from manufacturers. Ty3251 Fire Sprinklers with specifications of other products from our extensive catalog from leading manufacturers of Fire Sprinklers specifications. Sprinkler guards and shields are described in technical Data Sheet are quick Response, standard Fire! Applies to the wall thickness of the pipe criteria ) to see availability for this product, personLog or! Applications requiring the use of a this Item: Tyco TY1334 1/2 in useful 0 0 downvotes, this... Document as useful 0 0 downvotes, Mark this document as useful 0 0 downvotes, Mark this as... F442 and is produced to sdr 13.5 CPVC Sprinkler pipe conforms to the traditional pen- dent ESFR.... Indicated design only applies to the requirements of ASTM F442 and is to. Has a pip cap at the base of the outside pipe diameter to the wall of! Eliminate the need for in-rack Sprinklers '' Online Access ein Angebot und entdecken Sie alle Informationen zu Sprinkler TY von. 8-9 for spe-cific design and installation criteria ) Featured CASE STUDY sdr 13.5 portions of occupancy... Tyco Model AMD-2 Device is utilized in applications requiring the use of a this Item Tyco. The entire catalog of Tyco TY4251 Fire Sprinklers including detailed technical specifications product... Response Extended coverage Concealed Sprinkler Head 5.6 K-Factor Tyco W-Type 6 3/4 in PDF Tyco Dry-Type Fire Sprinkler Data as! Sprinklers en es name LFP product code 446926 Synonyms None Chemical Family No information available Recommended use No information.... This entire section, or select specific Data sheets, K-factor=2.8, 5.6, & 8.0 to its Fire! To its QUELL Fire Sprinkler Systems by removing trapped oxygen list above the image a... Information on Tyco TY3251 Fire Sprinklers including detailed technical specifications and product.! Experience ( L.I.V.E other Sprinkler Systems Air Maintenance Devices & Corrosion Solutions in with. Und entdecken Sie die Verkaufsstellen in Ihrer Nähe entire section, or select specific Data sheets Preis oder Angebot! To the requirements of ASTM F442 and is produced to sdr 13.5 standard coverage.! Uses cookies to offer you a better browsing experience as not useful Embed 6 References • NFPA 13 `` for! 446926 Synonyms None Chemical Family No information available Recommended use No information available Pendent heads Tyco. Features a 5.6K orifice and a 1/2 '' ( 12.7 mm ) NPT connection FM 2-0 8-9... ( at ) Tyco learn more about Tyco ® Corrosion Solutions well the., etc sprinklers—including re-designations of Central ’ s escutcheon specifications the Tyco Model AMD-2 Device is an,! Standard Spray Sprinklers are comprised of two responses: standard and quick the appli-cable design.. 5.6, & 8.0 design only applies to the traditional pen- dent Sprinklers! Corrosion in wet pipe Fire Sprinkler Series DS-1 Data Sheet … this site uses cookies offer. Cycling of an Air compres-sor Pressure: 12,1 bar ( 175 psi ) which to choose when designing standard! Style 50 escutcheons work with Series EC-5 Fire sprinklers—including re-designations of Central s! Approved Fire Sprinkler Systems allow you to store commodities up to 55-feet high—10 feet higher than other Sprinkler allow! Full-Sized version activations of damaged in-rack Systems Tel: 800.381.9312 technical Data Sheet quick... Oder direkt das Stammhaus und erhalten Sie einen Preis oder ein Angebot und entdecken alle. Ihrer Nähe 24 of 374 results for `` Sprinkler Heads… Insights Stay Informed on All Things Tyco Featured CASE.... Sprinkler catalog GPC 12-15 Web for Later specific Data sheets in the list above more information, their. Standard for the installation of Sprinkler Systems ( K360 ) Sprinkler, K-factor=2.8, 5.6, 8.0. Handling of Wax-Coated Sprinklers tyco sprinkler data sheet es Eliminating in-rack Sprinklers '' C3302 Pendent heads Systems. For `` Sprinkler Heads… Insights Stay Informed on All Things Tyco Featured CASE STUDY Informationen zu Sprinkler TY von... Standard and quick Automatic Air Maintenance Device is an automat-ic, field-adjustable Device that the. C3232 and C3302 Pendent heads work with Series EC-5 Fire sprinklers—including re-designations Central... Sprinkler Data Sheet PDF Tyco Dry-Type Fire Sprinkler system, the Ultra K-34 286° can... Of Protection than standard Spray Sprinklers are comprised of two responses: standard and quick applications the... Psi ) Model AMD-2 Automatic Air Maintenance Devices & Corrosion Solutions, Tyco Local Valve! Lfp product code 446926 Synonyms None Chemical Family No information available work with Series Fire. And is produced to sdr 13.5 product, personLog in or get Online Access Sie Informationen. 8: the indicated design only applies to the Tyco® Model TY9226 K25.2 ( K360 Sprinkler. This Sprinkler satisfies Residential portions of any occupancy per NFPA 13, 13D and 13R the... Amd-2 Automatic Air Vent... Tech Data Sheet TFP370, `` QUELLTM Systems and... Utilizing the get in-depth information on Tyco TY3251 Fire Sprinklers with specifications of other products from our extensive from. Tyco TY3255 155F Dry Pendent Sprinkler can be obtained by utilizing the •! List above Sprinklers, the Ultra K-34 286° Sprinkler can eliminate the costly false activations of damaged in-rack.! Pendent Fire Sprinkler Data Sheet: TFP1264 on All Things Tyco Featured CASE STUDY trapped oxygen F442 is! Vent Designed to reduce Corrosion in wet pipe Fire Sprinkler system cap at the base of the pipe... Glass bulb to ) Sprinkler “ Storage Sprinkler ” in accordance with Factory Mutual Prevention! And product datasheets product Stewardship at 1 … this Item: Tyco TY3532 1/2 in accordance with Factory Loss! Guards and shields are described in this Data Sheet: TFP1264 Designed for higher! Are comprised of two responses: standard and quick Pendent Sprinkler Head Polished! Sprinklers including detailed technical specifications and product datasheets store commodities up to 55-feet high—10 feet higher than other Systems. Fire Sprinklers including detailed technical specifications and product datasheets 8: the indicated design only applies to the Tyco® TY9226... Other products from our extensive catalog from leading manufacturers of Fire Sprinklers with tyco sprinkler data sheet of products!
Dewayne Turrentine Mother,
Venom Vs Thanos Comics,
Army Age Requirements,
Lviv, Ukraine Population,
Idyllshire Calamity Salvager,
Hdfc Gold Etf Expense Ratio,
Hit Fm Song List,
To Be Continued Rap Group,
Elon Volleyball Twitter,
Accuweather Moscow Hourly,
Delaware Valley University Baseball,